A filter whose Laplace transform is of the form (s–z)/(s–p), where z and p are negative and the magnitude of z is greater than that of p. Such filters can help to reduce the steady-state error in a closed-loop control system. They are often used in conjunction with lead filters to improve frequency response. See also s-domain circuit analysis.